Troubleshoot a unit
Log in with the app account the unit is set up on. You'll see its live sensors from anywhere, no WiFi needed.
- The password is used once to log in to Midea. It is not saved anywhere.
- Only units on that account show up. On a customer's unit, use their login, or have them share the unit to your account in the app.
- Google/Apple sign-in accounts have no password: set one in the app first (Me → account → password).
- "Carrier / NetHome Plus" is for units in the Carrier Air Conditioner, Carrier CliMate or NetHome Plus apps (one shared login).
Pick a unit
Unit
Reading the unit…
* T3 outdoor coil reading is approximate on some models.
Last 10 minutes
Always on, every minute, kept 180 days, even with the app closed. The chart fills in from it when you come back. If your login expires, the data is kept and you just log in again.
Your Carrier log
Diagnosis rule of thumb
- Waiting for the first reading…
Reads every 15 s while this page is open, plus a full scan of all groups about once a minute. Diagnosis is a rule-of-thumb guide only, always confirm with gauges and meters.
Piping diagram
Saved for this unit, so it only asks once.
Waiting for the first reading…
Tap a sensor dot for what it is and its normal range.
Request this model: text the outdoor model to Tab and I'll look up its manual and add its exact diagram.
History
Error codes and abnormal cycles, newest first, saved on this phone. Tap one for the readings at that moment.
Nothing saved yet: no error codes or abnormal cycles seen.
What's checked
Readings this unit doesn't send. A tile moves to the main screen by itself as soon as the unit sends a value for it.
Electrical & outdoor
Asked of every unit. Grey = the unit sent 0 or didn't answer. "unverified" = the byte's meaning or scale isn't confirmed on a real unit yet.
Raw data (every group)
Each group's reply in hex. Highlighted = non-zero data bytes (grey = header). Tap a byte to see its number. Useful on a new model: any highlighted byte is data the unit sends.
Control
Waiting for the first reading…
Mode
Fan speed
Swing
Options
Holds ~46°F (heat). For empty houses.
Honeywell thermostats
Thermostat
Sensors
On / off cycles
Alerts
Details
More data (0 fields)
Raw changes (every field Honeywell sends)
Every value in the thermostat's cloud data that changed, old → new. Change a setting on the thermostat, tap “Read now”, and see which field moved.
Reads every 2 min, so on/off times are within ±2 min. Kept 60 days. Changes go to a thermostat only from the Control tab, when you press.
M-NET systems
Open the M-NET link Tab sent you on this phone, or paste it here.
M-NET systems
No M-NET reader connected yet
To connect one: tap + Add site, give it the customer's name, then run the install line it shows on the reader box at that site (with the PAC-USCMS-MN-1 plugged in and internet). The site shows up here after the box's first upload.
Each box reads its M-NET bus and uploads here. A box is Offline when it hasn't uploaded for 5 min.
Units
Errors
Site settings
Add an M-NET site
Shown only once. Copy it now; it goes only on this site's box.
The old token stopped working. Run the install line again on the box.
The installer isn't published yet: Tab will send the final install address. The token above already works.
Samsung
Open the Samsung link Tab sent you on this phone, or paste it here.
Join Wi-Fi 'Samsung-Reader' first
Samsung
F1/F2 bus reader
Join Wi-Fi 'Samsung-Reader' first
Waiting for your Samsung reader
Finish the install, it shows here within a minute.
The reader sends a reading every 30 seconds once it's on your Wi-Fi and wired to F1/F2.
Piping diagram
History
Drag a finger along the chart: the box shows that moment's time and every reading, and the diagram above moves with it. Pinch with two fingers to zoom.
Units
Buttons greyed out or not working?
- The reader must be online, and “Allow remote control” must be on (here and on the reader's own page).
- On a VRF, each indoor unit must have central control turned on (installation option SEG5 = 1), and another central controller or Wi-Fi kit on the bus can override changes.
- On a system with more than one indoor unit, Mode changes go to all units together: mixed heat and cool on one outdoor unit trips error E161.
Actual vs target
Indoor & power
Outdoor unit
Unit info
What the unit itself reports on F1/F2 (Samsung's own codes, S-NET Pro 2).
Change Wi-Fi
- On the reader's page tap “Wi-Fi setup mode (10 min hotspot)”, or hold the reader's button 5 s until the light turns blue.
- When the light blinks blue, join the Wi-Fi “Samsung-Reader” on your phone.
- The setup page opens; if it doesn't, go to 192.168.4.1.
- Pick the new network and type its password.
- The light turns green when it's connected, and readings show here again.
Not finished in 10 minutes? It goes back to the old network on its own. Holding the button 15 s (light red) forgets all saved Wi-Fi. It remembers the last 3 networks.
Details charts, more readings, commands, raw data
Pressures are converted from the unit's own bus reading; whether they are gauge or absolute isn't verified yet.
More readings
Last hours
Recent commands
Raw data (latest push)
Bus log
Raw lines the reader saw on the F1/F2 bus (newest at the bottom, last 300). Refresh
Loading…
Readings come from the reader on your F1/F2 bus. The unit is only changed when you press a control with “Allow remote control” on. Offline when no reading for 2 min.